FINAL TOOLBOX
03 // 双方向STEM・金融・実用計算機 // 流体・構造・電気・機械工学の計算機COP = Q_thermal / W_in

成績係数(COP)ヒートポンプ・冷凍機計算機

COP = Q_thermal / W_elec の式から、エアコンやヒートポンプの成績係数(COP)、冷暖房能力、または圧縮機の消費電力を計算します。

COP = Q_thermal / W_in
求めたい項目を選択してください(どの入力欄に直接入力しても自動切替されます):計算対象: COP — Coefficient of Performance
算出値

Thermal Watts moved per electrical Watt consumed

0.512
unit

Thermal capacity in Watts (switch unit to kW)

1001,000,000.00

Electrical power consumed in Watts (switch unit to kW)

50500,000.00
計算結果 · Coefficient of Performance (COP)
3.8

ステップ別の計算過程

01Canonical Law: COP = Q_thermal / W_in
02Given Inputs (Base Units): Q_thermal = 11,400 W, W_in = 3,000 W
03Solve for COP (Coefficient of Performance): COP = 3.8

The Coefficient of Performance (COP) measures heat pump or chiller efficiency as the ratio of useful thermal heat moved Q_thermal to electrical compressor work input W_in: COP = Q_thermal / W_in.

実生活・実務の目安

Electric Resistance BaseboardCOP = 1.00

1 kW electricity produces exactly 1 kW heat

Inverter Air-Source Heat PumpCOP = 3.2 – 4.5 (at 7 °C)

Moves 3.2–4.5× more heat energy than electricity used

Centrifugal Water-Cooled ChillerCOP = 5.5 – 7.0

EER = COP × 3.41214 BTU/(Wh)

20段階の比較早見表

Coefficient of Performance (COP) · Thermal Heating/Cooling Output (Q_thermal)

Coefficient of Performance (COP) Heat Pump & Chiller Solver — Thermal Heating/Cooling Output → Coefficient of Performance
#Thermal Heating/Cooling Output (W)Coefficient of Performance (COP)Δ %
01100 W0.033333 -99.12%
0211,400.00 W現在値3.8 0.00%
0315,761.71 W5.2539 +38.26%
0423,592.57 W7.8642 +106.95%
0531,423.42 W10.4745 +175.64%
0639,254.28 W13.0848 +244.34%
0747,085.13 W15.695 +313.03%
0854,915.99 W18.3053 +381.72%
0962,746.84 W20.9156 +450.41%
1070,577.70 W23.5259 +519.10%
1178,408.55 W26.1362 +587.79%
1286,239.41 W28.7465 +656.49%
1394,070.26 W31.3568 +725.18%
14101,901.12 W33.967 +793.87%
15109,731.97 W36.5773 +862.56%
16117,562.83 W39.1876 +931.25%
17125,393.68 W41.7979 +999.94%
18133,224.54 W44.4082 +1068.64%
19141,055.39 W47.0185 +1137.33%
20148,886.25 W49.6288 +1206.02%
このツールは役に立ちましたか?

よくある質問(FAQ)

成績係数(COP)ヒートポンプ・冷凍機計算機の使い方は?+

数値を入力するかスライダーを動かすだけで、成績係数(COP)ヒートポンプ・冷凍機計算機(数式: COP = Q_thermal / W_in)をブラウザ上で即座に計算・視覚化できます。COP = Q_thermal / W_elec の式から、エアコンやヒートポンプの成績係数(COP)、冷暖房能力、または圧縮機の消費電力を計算します。

成績係数(COP)ヒートポンプ・冷凍機計算機の計算結果やグラフは保存できますか?+

はい。計算結果のワンクリックコピーに加え、高解像度のSVG・PNG画像、CSVデータ、印刷用ワークシートとして即座に出力できます。

成績係数(COP)ヒートポンプ・冷凍機計算機のサンプルデータを消去して白紙から入力できますか?+

はい。ツール上部のクリア(白紙から開始)ボタンを押すとすべての入力欄がリセットされ、いつでもサンプルデータを再読み込みできます。